HL series |
Piston
compressor units mounted on a base plate
2.2 - 37 kW
10 - 35 bar
Driven by means of V-belt |
- Up to 3,0 kW: motor
protection switch with mechanical relief valve and on/off switch.
- Wet suction
filters, as from 15 kW dry suction filters.
- Safety valve and
non-return valve.
- Spiral tube cooler
resp. after cooler.
- Belt guard
according to the accident prevention regulations.
- Condensate drain
valve.
- Motor retensioning
with parallel clamping guide.
- Starting solenoid
valve.
- Pressure switch for
receiver mounting
|
 |
| Type |
Piston
displacement
1/min
|
Volume
flow rate according
to DIN 1945 at 8
bar, 1/min
|
Operating
pressure
(gauge) bar pe
|
No.
of cylinders |
Motor
output
kW
|
Compressor
speed
min-1
|
Compressed
air connection
R"
|
Net
weight
kg
|
Approx.
dimension of compressor system (cm abt.) |
| Length |
Width |
Height |
| 10
bar, single stage, three phase current |
| HL
041012 |
407 |
296 |
10 |
2 |
2,2 |
960 |
1/2 |
100 |
74 |
38 |
51 |
| HL
051012 |
501 |
370 |
10 |
2 |
3,0 |
810 |
1/2 |
110 |
74 |
38 |
52 |
| HL
081012 |
693 |
512 |
10 |
2 |
4,0 |
660 |
1/2 |
130 |
89 |
51 |
59 |
| HL
091012 |
909 |
665 |
10 |
2 |
5,5 |
866 |
1/2 |
160 |
89 |
51 |
59 |
| HL
131013 |
1346 |
985 |
10 |
3 |
7,5 |
855 |
3/4 |
210 |
109 |
54 |
69 |
| HL
181013 |
1790 |
1338 |
10 |
3 |
11,0 |
1135 |
3/4 |
230 |
109 |
54 |
69 |
| HL
211014 |
1941 |
1456 |
10 |
4 |
11,0 |
815 |
1 |
320 |
149 |
59 |
70 |
| HL
221014 |
2227 |
1640 |
10 |
4 |
15,0 |
935 |
1 |
330 |
149 |
59 |
70 |
| 10
bar, double stage, three phase current |
| HL
251024 |
2565 |
2160 |
10 |
4 |
15,0 |
840 |
1
1/2 |
410 |
152 |
66 |
82 |
| HL
301024 |
3050 |
2550 |
10 |
4 |
18,5 |
998 |
1
1/2 |
430 |
152 |
66 |
82 |
| HL
401024 |
3790 |
3200 |
10 |
4 |
22,0 |
735 |
1
1/2 |
485 |
168 |
69 |
92 |
| HL
501024 |
4640 |
3870 |
10 |
4 |
30,0 |
900 |
1
1/2 |
535 |
168 |
69 |
92 |
| HL
551024 |
5615 |
4620 |
10 |
4 |
37,0 |
1090 |
1
1/2 |
570 |
168 |
73 |
92 |
| 15
bar, double stage, three phase current |
| HL
041522 |
356 |
290 |
15 |
2 |
3,0 |
1150 |
1/2 |
100 |
89 |
51 |
64 |
| HL
051522 |
515 |
420 |
15 |
2 |
4,0 |
975 |
1/2 |
135 |
92 |
51 |
64 |
| HL
081523 |
810 |
675 |
15 |
3 |
5,5 |
770 |
3/4 |
165 |
133 |
54 |
71 |
| HL
101523 |
1020 |
845 |
15 |
3 |
7,5 |
960 |
1 |
165 |
133 |
54 |
71 |
| HL
131523 |
1296 |
1075 |
15 |
3 |
11,0 |
1220 |
1 |
185 |
133 |
54 |
71 |
| HL
151524 |
1625 |
1360 |
15 |
4 |
11,0 |
910 |
1 |
320 |
168 |
59 |
70 |
| HL
201524 |
2090 |
1695 |
15 |
4 |
15,0 |
1170 |
1 |
340 |
168 |
66 |
70 |
| HL
221524 |
2335 |
1960 |
15 |
4 |
15,0 |
765 |
1
1/2 |
410 |
185 |
66 |
82 |
| HL
251524 |
2720 |
2270 |
15 |
4 |
18,5 |
890 |
1
1/2 |
430 |
185 |
66 |
82 |
| HL
401524 |
3250 |
2730 |
15 |
4 |
22,0 |
630 |
1
1/2 |
485 |
189 |
69 |
92 |
| HL
501524 |
4255 |
3550 |
15 |
4 |
30,0 |
825 |
1
1/2 |
545 |
189 |
69 |
92 |
| HL
551524 |
4950 |
4060 |
15 |
4 |
37,0 |
960 |
1
1/2 |
575 |
196 |
73 |
92 |
| 35
bar high (pressure), double stage, three phase current |
| HL
023522 |
210 |
110 |
35 |
2 |
2,2 |
675 |
1/2 |
90 |
89 |
38 |
55 |
| HL
033522 |
280 |
225 |
35 |
2 |
3,0 |
900 |
1/2 |
95 |
89 |
38 |
55 |
| HL
043522 |
400 |
292 |
35 |
2 |
4,0 |
780 |
1/2 |
145 |
89 |
51 |
64 |
| HL
053522 |
500 |
380 |
35 |
2 |
5,5 |
975 |
1/2 |
155 |
89 |
51 |
64 |
| HL
083523 |
800 |
525 |
35 |
3 |
7,5 |
765 |
3/4 |
220 |
109 |
54 |
71 |
| HL
103523 |
1050 |
710 |
35 |
3 |
11,0 |
1000 |
3/4 |
220 |
109 |
54 |
71 |
|
Optional
auxiliary equipment
- Working hour meter
- Oil - niveau
control
- Combi control
- Current measuring
and cutout relay
- Rubber metal
supports for elastic bearing
- Flexible hose
- Dry suction filters
up to 11 kW
- As from 4.0 kW
automatic star delta combination with electric solenoid valve and hour
meter
|
|
Updated